Backwater lifting station Ecolift
DN 100, exposed
The backwater lifting station for faecal and non-faecal wastewater is equipped with one pump and one motor-driven closure system. The pipe cross-section is normally open and the water drains to the sewer via natural fall. Backwater is detected by an optical probe, which causes the motor-driven closure system to close automatically. During the backwater phase, the water drains via a pressure pipe, which carries the wastewater above the backwater level and into the sewer. Connection hole in the drain body for installation in the ground, incl. seal for pressure pipe and cable conduit. The station is controlled by a user-friendly control unit, which is optionally integrated in the building management system via a potential-free contact, or alarm and collective fault messages can be output via a GSM interface.
- Hybrid function: uses the natural fall to the sewer - pump is only used in case of backwater
- Quiet and energy-saving
- Double safety due to backwater flap and pressure pipe
Item no. | 21100 |
---|---|
GTIN | 4026092046760 |
Price group | 20 |
Backwater lifting station Ecolift DN 100, exposed
The backwater lifting station for faecal and non-faecal wastewater is equipped with one pump and one motor-driven closure system. The pipe cross-section is normally open and the water drains to the sewer via natural fall. Backwater is detected by an optical probe, which causes the motor-driven closure system to close automatically. During the backwater phase, the water drains via a pressure pipe, which carries the wastewater above the backwater level and into the sewer. Connection hole in the drain body for installation in the ground, incl. seal for pressure pipe and cable conduit. The station is controlled by a user-friendly control unit, which is optionally integrated in the building management system via a potential-free contact, or alarm and collective fault messages can be output via a GSM interface. Type of wastewater: wastewater with sewage Installation situation: exposed drainage pipe Version: Emergency closure: yes Pump control: Control unit Passage seal for conduit pipe (DN): 50 mm Delivery state: Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected) Number of motor-driven backwater flaps: 1 General characteristics: Nominal size (DN): 100 Outer diameter (OD): 110 Colour: black Approval: Z-53.2-487 Dimensions: Length: 642 mm Width: 243 mm Height: 405 mm Tank: Pressure pipe connection (OD): 40 mm Drain body: Socket version: including spigot and socket Coverage features: Type of cover: - Pumping device: Pump: SPZ 1000 Number of pumps: 1 Max. pumping capacity: 11.5 m3/h Max. pumping height: 10 m Operating mode: S3 - 50 % Power P1: 1.2 kW Power P2: 0.69 kW Speed: 2,800 U/min Type of fuse required (electrical protection): C 16 A Max. temperature (permanent) of conveyed material: 40 °C Connection type: coded plug Weight: 10 kg Impeller type: Macerator Length of mains cable for pump: 5 m Rated current: 5.2 A Protection class (pump): IP 68 (3m/48h) Protection class: I Type of pump connection cable: H07RN-F 3G 1.0 mm2 Temperature monitoring: integrated Cos phi - power factor: 0.97 Insulation class: F Vertical drop between inlet and outlet: 9 mm Motor type: KSM 140 Protection class motor: IP 68 (3m/48h) Protection class probe: IP 68 (3m/48h) Control: Control unit: Comfort Operating voltage: 230 V Mains frequency: 50 Hz Self-diagnosis system (SDS): yes Battery buffering: yes Multi-line display: yes Log book function: yes USB interface: no GSM interface: no Potential-free contact: yes Standby power: 5 W Protection class control unit: IP 54 Length of mains cable for control unit: 1.4 m Type of level measurement: optical Level measurement instrument: optical probe Alarm sensor: optical probe
Installation Video
Title | Item no. |
---|
Title | Item no. |
---|
Title | Item no. | ||
---|---|---|---|
Remote signal generator 20 m cable, 2x0.75 q | 20162 | Show | |
Pressure pipe set 5 m pressure hose, DA 40 mm | 28040 | Show | |
Clearance code for potential-free contact | 80077 | Show | |
10 m probe cable extension set | 80889 | Show | |
Cable extension set for motor 10 m | 80890 | Show | |
Cable prolongation set for pump 10 m | 80891 | Show |
Title | Item no. | ||
---|---|---|---|
Cover Ecolift outlet side | 21056 | Show | |
Pump cover inlet side | 28052 | Show | |
Vent for Pumpfix Premium | 28060 | Show | |
Active carbon filter | 28061 | Show | |
Pumpfix F Control Unit Komfort - IP 54 | 28071 | Show | |
Replacement pump AqualiftF/Pumpfix F | 28351 | Show | |
One-handed closure for backflow preventer | 680018 | Show | |
Battery 9 V block | 680034 | Show | |
Flap holder for motor-driven and mechanical flap | 680101 | Show | |
Pressure pipe connection Ecolift, installation with exposed pipe | 680102 | Show | |
Gasket set (Pumpfix, Ecolift) | 70319 | Show | |
Motor-driven backwater flap Premium | 80038 | Show | |
Insert part f. motor-driven flap Premium | 80039 | Show | |
Staufix FKA drive motor (KSM 140) 5m | 80076 | Show | |
Replacement set optical probe | 80888 | Show | |
Adapter set optical probe | 80892 | Show | |
Staufix Premium Spigot DN 100 | 83081 | Show | |
Staufix Premium Socket DN 100 | 83085 | Show |
Manuals | |
---|---|
CAD Data | |
Approval | |
Test Reports and Certificates | |
Declaration of Performance |
- Installation situation (ATTR-1): exposed drainage pipe
- Country of origin (ATTR-322): DE
- Start-up current (ATTR-285): 14.9 AMP
- Pump (ATTR-4): SPZ 1000
- Number of pumps (ATTR-181): 1
- Impeller type (ATTR-8): Macerator
- Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.0 mm2
- Type of fuse required (electrical protection) (ATTR-N3): C 16 A
- Max. permissible switching frequency (ATTR-162): 20 1PH
- Operating mode (ATTR-10): S3 - 50 %
- Power P1 (ATTR-F4): 1.2 KWT
- Power P2 (ATTR-F5): 0.7 KWT
- Speed (ATTR-F2): 2,800 UMIN
- Rated current (ATTR-N5): 5.2 AMP
- Max. pumping capacity (ATTR-F7): 11.5 MQH
- Max. pumping height (ATTR-F8): 10 MTR
- Max. temperature (permanent) of conveyed material (ATTR-132): 40 CEL
- Protection class (ATTR-133): I
- Connection type (ATTR-N1): coded plug
- Protection class (pump) (ATTR-125): IP 68 (3m/48h)
- Length of mains cable for pump (ATTR-11): 5 MTR
- Temperature monitoring (ATTR-135): integrated
- Weight (ATTR-191): 10 KGM
- Cos phi - power factor (ATTR-192): 1.0
- Insulation class (ATTR-193): F
- Expected service life (hours of operation) (ATTR-194): 5,000 HUR
- Expected service life (number of switching cycles) (ATTR-195): 150,000
- Nominal size (DN) (ATTR-118): 100
- Outer diameter (OD) (ATTR-147): 110
- Net weight (ATTR-A3A): 20 KGM
- Gross weight (ATTR-A3B): 25.5 KGM
- Length (ATTR-A6A): 642 MMT
- Width (ATTR-A6B): 243 MMT
- Height (ATTR-A6C): 405 MMT
- Volume (ATTR-320): 0.1 MTQ
- Packaging dimension: length (ATTR-325): 785 MMT
- Packaging dimension: width (ATTR-326): 385 MMT
- Packaging dimension: height (ATTR-327): 465 MMT
- Dimensions (ATTR-323): 785X385X465MM
- Number of packages (ATTR-321): 1
- Emergency closure (ATTR-153): yes
- Pump control (ATTR-134): Control unit
- Socket version (ATTR-233): including spigot and socket
- Control unit (ATTR-S2): Comfort
- Self-diagnosis system (SDS) (ATTR-S5): yes
- Battery buffering (ATTR-S6): yes
- Multi-line display (ATTR-S7): yes
- Log book function (ATTR-S8): yes
- USB interface (ATTR-S9): no
- GSM interface (ATTR-S10): no
- Potential-free contact (ATTR-S11): yes
- Length of mains cable for control unit (ATTR-S12): 1.4 MTR
- Operating voltage (ATTR-S13): 230 VLT
- Mains frequency (ATTR-S14): 50 HTZ
- Protection class control unit (ATTR-S4): IP 54
- Alarm sensor (ATTR-S1): optical probe
- Type of level measurement (ATTR-7A): optical
- Level measurement instrument (ATTR-7B): optical probe
- Pressure pipe connection (OD) (ATTR-B18): 40 MMT
- Type of cover (ATTR-A21): -
- Passage seal for conduit pipe (DN) (ATTR-184): 50 MMT
- Declaration of Performance (DOP) (ATTR-292): 009-036
- Wastewater quantity (ATTR-310): Medium
- Protection strategy (ATTR-311): Central protection
- Type of wastewater (ATTR-6): wastewater with sewage
- Position relative to sewer (ATTR-309): Gradient to the sewer
- Function in the event of backwater (ATTR-312): Drains in the event of backwater
- Protection class probe (ATTR-175): IP 68 (3m/48h)
- Colour (ATTR-102): black
- Protection class motor (ATTR-174): IP 68 (3m/48h)
- Motor type (ATTR-120B): KSM 140
- Approval (ATTR-A5): Z-53.2-487
- CE marking (ATTR-A5B): no
- Number of motor-driven backwater flaps (ATTR-3A): 1
- External monitoring (ATTR-A8): LGA
- Vertical drop between inlet and outlet (ATTR-176): 9 MMT
- Delivery state (ATTR-189): Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected)
- Declaration of conformity (ATTR-289): yes
- Brand (M-ATTR-001): KESSEL
- Product group (M-ATTR-002): Hybrid lifting stations
- Product type (M-ATTR-003): Backwater lifting station
- Product family (M-ATTR-004): Ecolift
- Product name (M-ATTR-005): Ecolift
- Standby power (ATTR-S20): 5 WTT