Backwater pumping station Pumpfix S
DN 100, with black cover plate
The backwater pumping station for faecal-free wastewater is equipped with one pump and two mechanical backwater valves which close automatically in the event of backwater. Normally, draining takes place via the natural gradient to the sewer. During the backwater phase, draining takes place via the integrated pump against backwater pressure directly into the sewage channel. - With vertically adjustable upper section for continuous height and level compensation and integrated floor drain - System suitable for installation in waterproof concrete, groundwater resistant up to 3 m - Backwater protection in accordance with EN 13564 type 5 - Including socket DN 50 for inlet and cable conduit - Pump suitable for permanent operation with multi-vane impeller for maximum operational safety - Including float switch for level measurement
- Drains reliably against backwater pressure
- Pump suitable for permanent operation with multi-vane impeller for maximum operating safety
- System suitable for installation in waterproof concrete
Item no. | 280451S |
---|---|
GTIN | 4026092085516 |
Price group | 10 |
Backwater pumping station Pumpfix S DN 100, with black cover plate
The backwater pumping station for faecal-free wastewater is equipped with one pump and two mechanical backwater valves which close automatically in the event of backwater. Normally, draining takes place via the natural gradient to the sewer. During the backwater phase, draining takes place via the integrated pump against backwater pressure directly into the sewage channel. - With vertically adjustable upper section for continuous height and level compensation and integrated floor drain - System suitable for installation in waterproof concrete, groundwater resistant up to 3 m - Backwater protection in accordance with EN 13564 type 5 - Including socket DN 50 for inlet and cable conduit - Pump suitable for permanent operation with multi-vane impeller for maximum operational safety - Including float switch for level measurement Type of wastewater: wastewater without sewage Version: Type of waterproofing layer: Waterproofing layer Note on installation depth: System suitable for installation in waterproof concrete Delivery state: plug-in ready Backwater protection: Type 5 Number of mechanical backwater flaps: 2 General characteristics: Nominal size (DN): 100 Outer diameter (OD): 110 Standard: EN 13564, EN 1253-1 Dimensions: Length: 485 mm Width: 380 mm Cutout dimension, length: 600 mm Cutout dimension, width: 600 mm Tank: Inlet nominal size (DN): 50 Connection conduit pipe (DN): 50 Installation depth: 330 - 460 mm Groundwater resistant from lower edge of base section: 3000 mm Coverage features: Type of cover: Cover plate Cover material: Polymer Colour of cover: black Drainage function: yes Load class: K 3 (EN 1253-1) Length: 366 mm Width: 366 mm Locking: Lock & Lift Grating: Rim length: 380 mm Rim width: 380 mm Shape of upper section: square Discharge rate (l/s) with 20 mm backwater: 1.6 l/s Pumping device: Pump: GTF 500 Number of pumps: 1 Max. pumping capacity: 10 m3/h Max. pumping height: 8 m Operating voltage: 230 V Mains frequency: 50 Hz Operating mode: S1 Power P1: 600 kW Power P2: 360 kW Speed: 2,800 U/min Type of fuse required (electrical protection): C 16 A Max. temperature (permanent) of conveyed material: 40 °C Connection type: Schuko (earthed contact) 2-pin Weight: 6 kg Impeller type: Multi-vane impeller Length of mains cable for pump: 5 m Rated current: 2.7 A Protection class (pump): IP 68 Protection class: I Type of pump connection cable: H07RN-F 3G 1.0 mm2 Temperature monitoring: integrated Cos phi - power factor: 0.91 Insulation class: F
Title | Item no. |
---|
Title | Item no. |
---|
Title | Item no. | ||
---|---|---|---|
Odour trap Multistop, System 125 | 48500 | Show | |
Odour trap Megastop | 48550 | Show | |
Hair filter Polymer, for System 125 bathroom drains | 48700 | Show | |
Odour trap for The Ultraflat 79 | 680696 | Show | |
Drain body for cover plate for odour trap 50 mm, black | 680795 | Show | |
Drain body for cover plate for Multistop, black | 680796 | Show | |
Drain body for cover plate for odour trap 50 mm, grey | 680797 | Show | |
Drain body for cover plate for Multistop, grey | 680798 | Show | |
Cover, watertight, black | 830050 | Show | |
Cover, watertight, tile-over | 830052 | Show | |
Extension section deeper installation, Flange/mating flange | 830073 | Show | |
Extension section Floor slab, for waterproof concrete | 830075 | Show |
Catalog Page | |
---|---|
Manuals | |
CAD Data | |
Declaration of Performance |
- Nominal size (DN) (ATTR-118): 100
- Outer diameter (OD) (ATTR-147): 110
- Complete article (ATTR-254): no
- Electrical connection available (ATTR-256): yes
- Shape of upper section (ATTR-259): square
- Type of drainage (ATTR-260): Point drain
- Grating/channel shape (ATTR-261): square
- Type of drainage (ATTR-263): open channel
- Advantages text (M-ATTR-007): Reliable drainage in case of backwater – including for waterproof concrete!
- Country of origin (ATTR-322): DE
- - (ATTR-370):
- Pump (ATTR-4): GTF 500
- Net weight (ATTR-A3A): 10.8 KGM
- Gross weight (ATTR-A3B): 12.1 KGM
- Installation depth (ATTR-B2_VB): 330 MMT
- Groundwater resistant from lower edge of base section (ATTR-B12): 3,000 MMT
- Note on installation depth (ATTR-188): System suitable for installation in waterproof concrete
- Type of waterproofing layer (ATTR-170): Waterproofing layer
- Inlet nominal size (DN) (ATTR-B1CA): 50
- Connection conduit pipe (DN) (ATTR-B3): 50
- Type of cover (ATTR-A21): Cover plate
- Rim length (ATTR-111B): 380 MMT
- Colour of cover (ATTR-A2A): black
- Rim width (ATTR-111C): 380 MMT
- Load class (ATTR-A2B): K 3 (EN 1253-1)
- Locking (ATTR-A2D): Lock & Lift
- Cover material (ATTR-A2E): Polymer
- Drainage function (ATTR-A2H): yes
- Odour trap (ATTR-A2I): yes
- Length (ATTR-A2M): 366 MMT
- Width (ATTR-A2N): 366 MMT
- Length (ATTR-A6A): 485 MMT
- Width (ATTR-A6B): 380 MMT
- Cutout dimension, length (ATTR-160): 600 MMT
- Cutout dimension, width (ATTR-161): 600 MMT
- Volume (ATTR-320): 0.1 MTQ
- Packaging dimension: length (ATTR-325): 445 MMT
- Packaging dimension: width (ATTR-326): 445 MMT
- Packaging dimension: height (ATTR-327): 466 MMT
- Dimensions (ATTR-323): 445X445X466MM
- Number of packages (ATTR-321): 1
- Type of wastewater (ATTR-6): wastewater without sewage
- Standard (ATTR-9): EN 13564
- Backwater protection (ATTR-151): Type 5
- Number of mechanical backwater flaps (ATTR-154): 2
- Discharge rate (l/s) with 20 mm backwater (ATTR-157): 1.6 LTS
- External monitoring (ATTR-A8): LGA
- Delivery state (ATTR-189): plug-in ready
- Declaration of Performance (DOP) (ATTR-292): 009-088
- Function in the event of backwater (ATTR-312): Drains in the event of backwater
- Wastewater quantity (ATTR-310): Medium
- Overall height (ATTR-313): min. 130 mm
- Type of operating voltage (ATTR-288): alternating voltage (AC)
- Brand (M-ATTR-001): KESSEL
- Product group (M-ATTR-002): Drains
- Product type (M-ATTR-003): Backwater pumping station
- Product family (M-ATTR-004): Pumpfix
- Product name (M-ATTR-005): Pumpfix S
- Number of pumps (ATTR-181): 1
- Impeller type (ATTR-8): Multi-vane impeller
- Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.0 mm2
- Type of fuse required (electrical protection) (ATTR-N3): C 16 A
- Operating mode (ATTR-10): S1
- Power P1 (ATTR-F4): 600 WTT
- Power P2 (ATTR-F5): 360 WTT
- Speed (ATTR-F2): 2,800 UMIN
- Operating voltage (ATTR-131): 230 VLT
- Mains frequency (ATTR-N4): 50 HTZ
- Rated current (ATTR-N5): 2.7 AMP
- Max. pumping capacity (ATTR-F7): 10 MQH
- Max. pumping height (ATTR-F8): 8 MTR
- Max. temperature (permanent) of conveyed material (ATTR-132): 40 CEL
- Protection class (ATTR-133): I
- Connection type (ATTR-N1): Schuko (earthed contact) 2-pin
- Protection class (pump) (ATTR-125): IP 68
- Length of mains cable for pump (ATTR-11): 5 MTR
- Temperature monitoring (ATTR-135): integrated
- Weight (ATTR-191): 6 KGM
- Cos phi - power factor (ATTR-192): 0.9
- Insulation class (ATTR-193): F
- Expected service life (hours of operation) (ATTR-194): 150,000 HUR
- Expected service life (number of switching cycles) (ATTR-195): 20