The backwater pumping station for faecal-free wastewater is equipped with one pump and two mechanical backwater valves which close automatically in the event of backwater. Normally, draining takes place via the natural gradient to the sewer. During the backwater phase, draining takes place via the integrated pump against backwater pressure directly into the sewage channel. - With vertically adjustable upper section for continuous height and level compensation and integrated floor drain - System suitable for installation in waterproof concrete, groundwater resistant up to 3 m - Backwater protection in accordance with EN 13564 type 5 - Including socket DN 50 for inlet and cable conduit - Pump suitable for permanent operation with multi-vane impeller for maximum operational safety - Including float switch for level measurement

  • Drains reliably against backwater pressure
  • Pump suitable for permanent operation with multi-vane impeller for maximum operating safety
  • System suitable for installation in waterproof concrete
Item no. 280451S
GTIN 4026092085516
Price group 10

    Backwater pumping station Pumpfix S DN 100, with black cover plate
    The backwater pumping station for faecal-free wastewater is equipped with one pump and two mechanical backwater valves which close automatically in the event of backwater. Normally, draining takes place via the natural gradient to the sewer. During the backwater phase, draining takes place via the integrated pump against backwater pressure directly into the sewage channel. - With vertically adjustable upper section for continuous height and level compensation and integrated floor drain - System suitable for installation in waterproof concrete, groundwater resistant up to 3 m - Backwater protection in accordance with EN 13564 type 5 - Including socket DN 50 for inlet and cable conduit - Pump suitable for permanent operation with multi-vane impeller for maximum operational safety - Including float switch for level measurement Type of wastewater: wastewater without sewage Version: Type of waterproofing layer: Waterproofing layer Note on installation depth: System suitable for installation in waterproof concrete Delivery state: plug-in ready Backwater protection: Type 5 Number of mechanical backwater flaps: 2 General characteristics: Nominal size (DN): 100 Outer diameter (OD): 110 Standard: EN 13564, EN 1253-1 Dimensions: Length: 485 mm Width: 380 mm Cutout dimension, length: 600 mm Cutout dimension, width: 600 mm Tank: Inlet nominal size (DN): 50 Connection conduit pipe (DN): 50 Installation depth: 330 - 460 mm Groundwater resistant from lower edge of base section: 3000 mm Coverage features: Type of cover: Cover plate Cover material: Polymer Colour of cover: black Drainage function: yes Load class: K 3 (EN 1253-1) Length: 366 mm Width: 366 mm Locking: Lock & Lift Grating: Rim length: 380 mm Rim width: 380 mm Shape of upper section: square Discharge rate (l/s) with 20 mm backwater: 1.6 l/s Pumping device: Pump: GTF 500 Number of pumps: 1 Max. pumping capacity: 10 m3/h Max. pumping height: 8 m Operating voltage: 230 V Mains frequency: 50 Hz Operating mode: S1 Power P1: 600 kW Power P2: 360 kW Speed: 2,800 U/min Type of fuse required (electrical protection): C 16 A Max. temperature (permanent) of conveyed material: 40 °C Connection type: Schuko (earthed contact) 2-pin Weight: 6 kg Impeller type: Multi-vane impeller Length of mains cable for pump: 5 m Rated current: 2.7 A Protection class (pump): IP 68 Protection class: I Type of pump connection cable: H07RN-F 3G 1.0 mm2 Temperature monitoring: integrated Cos phi - power factor: 0.91 Insulation class: F
      Title Item no.  
      Title Item no.  
      Title Item no.  
    Odour trap Multistop, System 125 48500 Show
    Odour trap Megastop 48550 Show
    Hair filter Polymer, for System 125 bathroom drains 48700 Show
    Odour trap for The Ultraflat 79 680696 Show
    Drain body for cover plate for odour trap 50 mm, black 680795 Show
    Drain body for cover plate for Multistop, black 680796 Show
    Drain body for cover plate for odour trap 50 mm, grey 680797 Show
    Drain body for cover plate for Multistop, grey 680798 Show
    Cover, watertight, black 830050 Show
    Cover, watertight, tile-over 830052 Show
    Extension section deeper installation, Flange/mating flange 830073 Show
    Extension section Floor slab, for waterproof concrete 830075 Show
      Title Item no.  
    Slotted cover 138x138 mm, Polymer 60101S Show
    • Nominal size (DN) (ATTR-118): 100
    • Outer diameter (OD) (ATTR-147): 110
    • Complete article (ATTR-254): no
    • Electrical connection available (ATTR-256): yes
    • Shape of upper section (ATTR-259): square
    • Type of drainage (ATTR-260): Point drain
    • Grating/channel shape (ATTR-261): square
    • Type of drainage (ATTR-263): open channel
    • Advantages text (M-ATTR-007): Reliable drainage in case of backwater – including for waterproof concrete!
    • Country of origin (ATTR-322): DE
    • - (ATTR-370):
    • Pump (ATTR-4): GTF 500
    • Net weight (ATTR-A3A): 10.8  KGM
    • Gross weight (ATTR-A3B): 12.1  KGM
    • Installation depth (ATTR-B2_VB): 330  MMT
    • Groundwater resistant from lower edge of base section (ATTR-B12): 3,000  MMT
    • Note on installation depth (ATTR-188): System suitable for installation in waterproof concrete
    • Type of waterproofing layer (ATTR-170): Waterproofing layer
    • Inlet nominal size (DN) (ATTR-B1CA): 50
    • Connection conduit pipe (DN) (ATTR-B3): 50
    • Type of cover (ATTR-A21): Cover plate
    • Rim length (ATTR-111B): 380  MMT
    • Colour of cover (ATTR-A2A): black
    • Rim width (ATTR-111C): 380  MMT
    • Load class (ATTR-A2B): K 3 (EN 1253-1)
    • Locking (ATTR-A2D): Lock & Lift
    • Cover material (ATTR-A2E): Polymer
    • Drainage function (ATTR-A2H): yes
    • Odour trap (ATTR-A2I): yes
    • Length (ATTR-A2M): 366  MMT
    • Width (ATTR-A2N): 366  MMT
    • Length (ATTR-A6A): 485  MMT
    • Width (ATTR-A6B): 380  MMT
    • Cutout dimension, length (ATTR-160): 600  MMT
    • Cutout dimension, width (ATTR-161): 600  MMT
    • Volume (ATTR-320): 0.1  MTQ
    • Packaging dimension: length (ATTR-325): 445  MMT
    • Packaging dimension: width (ATTR-326): 445  MMT
    • Packaging dimension: height (ATTR-327): 466  MMT
    • Dimensions (ATTR-323): 445X445X466MM
    • Number of packages (ATTR-321): 1
    • Type of wastewater (ATTR-6): wastewater without sewage
    • Standard (ATTR-9): EN 13564
    • Backwater protection (ATTR-151): Type 5
    • Number of mechanical backwater flaps (ATTR-154): 2
    • Discharge rate (l/s) with 20 mm backwater (ATTR-157): 1.6  LTS
    • External monitoring (ATTR-A8): LGA
    • Delivery state (ATTR-189): plug-in ready
    • Declaration of Performance (DOP) (ATTR-292): 009-088
    • Function in the event of backwater (ATTR-312): Drains in the event of backwater
    • Wastewater quantity (ATTR-310): Medium
    • Overall height (ATTR-313): min. 130 mm
    • Type of operating voltage (ATTR-288): alternating voltage (AC)
    • Brand (M-ATTR-001): KESSEL
    • Product group (M-ATTR-002): Drains
    • Product type (M-ATTR-003): Backwater pumping station
    • Product family (M-ATTR-004): Pumpfix
    • Product name (M-ATTR-005): Pumpfix S
    • Number of pumps (ATTR-181): 1
    • Impeller type (ATTR-8): Multi-vane impeller
    • Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.0 mm2
    • Type of fuse required (electrical protection) (ATTR-N3): C 16 A
    • Operating mode (ATTR-10): S1
    • Power P1 (ATTR-F4): 600  WTT
    • Power P2 (ATTR-F5): 360  WTT
    • Speed (ATTR-F2): 2,800  UMIN
    • Operating voltage (ATTR-131): 230  VLT
    • Mains frequency (ATTR-N4): 50  HTZ
    • Rated current (ATTR-N5): 2.7  AMP
    • Max. pumping capacity (ATTR-F7): 10  MQH
    • Max. pumping height (ATTR-F8): 8  MTR
    • Max. temperature (permanent) of conveyed material (ATTR-132): 40  CEL
    • Protection class (ATTR-133): I
    • Connection type (ATTR-N1): Schuko (earthed contact) 2-pin
    • Protection class (pump) (ATTR-125): IP 68
    • Length of mains cable for pump (ATTR-11): 5  MTR
    • Temperature monitoring (ATTR-135): integrated
    • Weight (ATTR-191): 6  KGM
    • Cos phi - power factor (ATTR-192): 0.9
    • Insulation class (ATTR-193): F
    • Expected service life (hours of operation) (ATTR-194): 150,000  HUR
    • Expected service life (number of switching cycles) (ATTR-195): 20