Skip to main content

Lifting station Minilift S

KTP 300-S1, Floor slab, tileable

The ready to plug in small lifting station for faecal-free wastewater is suitable for wastewater drainage of individual sanitary appliances. The submersible pump with float switch can be removed easily with the help of one-handed closures. The collection tank made of polymer (PE) has an open pump tank and is resistant to aggressive wastewater. The system for installation in the floor slab is preassembled for final installation on site. - with telescopic upper section for continuously adjustable height and level compensation and integrated floor drain - including backflow preventer for the pressure pipe - including DN 50 socket for inlet and cable conduit - pump with multi-vane impeller for maximum operating reliability - including float switch for level measurement

  • Space-saving installation in the floor slab
  • System ready to plug in
  • Easy maintenance
Item no. 280570X
GTIN 4026092082546
Price group 20

Lifting station Minilift S KTP 300-S1, Floor slab, tileable
The ready to plug in small lifting station for faecal-free wastewater is suitable for wastewater drainage of individual sanitary appliances. The submersible pump with float switch can be removed easily with the help of one-handed closures. The collection tank made of polymer (PE) has an open pump tank and is resistant to aggressive wastewater. The system for installation in the floor slab is preassembled for final installation on site. - with telescopic upper section for continuously adjustable height and level compensation and integrated floor drain - including backflow preventer for the pressure pipe - including DN 50 socket for inlet and cable conduit - pump with multi-vane impeller for maximum operating reliability - including float switch for level measurement Type of wastewater: wastewater without sewage Installation situation: floor slab installation Version: Type of system: Single station Pump control: Float switch Backflow preventer: integrated Delivery state: Installation-ready (connection parts must be connected on site) General characteristics: Colour: grey Standard: EN 12050-2 Dimensions: Length: 460 mm Width: 380 mm Tank: Inlet nominal size (DN): 50 Pumping volume: 7 l Pressure pipe connection (DN): 32 mm Pressure pipe connection (OD): 40 mm Installation depth: 330 - 460 mm Coverage features: Type of cover: tileable cover plate Cover material: Polymer Colour of cover: silver grey Max. flooring height: 16 mm Load class: K 3 (EN 1253-1) Length: 366 mm Width: 366 mm Locking: Lock & Lift Free passage: 10 mm Pumping device: Pump: KTP 300 Number of pumps: 1 Max. pumping capacity: 8 m3/h Max. pumping height: 6 m Operating voltage: 230 V Mains frequency: 50 Hz Operating mode: S1 Power P1: 0.34 kW Power P2: 0.21 kW Speed: 2,800 U/min Type of fuse required (electrical protection): C 16 A Max. temperature (permanent) of conveyed material: 40 °C Connection type: Schuko (earthed contact) 2-pin Impeller type: Multi-vane impeller Length of mains cable for pump: 5 m Rated current: 1.6 A Protection class (pump): IP 68 (3m) Type of pump connection cable: H07RN-F 3G 1.0 mm2 Temperature monitoring: integrated

Video

  Title Item no.  
  Title Item no.  
  Title Item no.  
Basic warning device with electronic probe 20222 Show
Basic warning device with optical probe 20223 Show
Adapter DN 50/70 27126 Show
Adapter DN 100/70 27602 Show
Pressure pipe set 5 m pressure hose, DA 40 mm 28040 Show
Adapter for pressure connection PE DA40 28086 Show
Inlet socket DN 50, with seal, Threaded ring 39005 Show
Inlet socket DN 70, with seal, Threaded ring 39007 Show
Odour trap Multistop, System 125 48500 Show
Odour trap Megastop 48550 Show
Hole saw for DN 50/70/100 500101 Show
Odour trap for The Ultraflat 79 680696 Show
Drain body for cover plate for odour trap 50 mm, black 680795 Show
Drain body for cover plate for Multistop, black 680796 Show
Drain body for cover plate for odour trap 50 mm, grey 680797 Show
Drain body for cover plate for Multistop, grey 680798 Show
Potential-free contact Extension set for control units Basic 80074 Show
Cover, watertight, black 830050 Show
Cover, watertight, tile-over 830052 Show
Extension section deeper installation, with flange 830070 Show
Seal for pipe penetration, DN 50 850114 Show
Seal for channel passage 75 mm 850116 Show
  Title Item no.  
Impeller replacement set KTP 300 28039 Show
Replacement pump for Minilift 28836 Show
Inlet socket DN 50, with seal, Threaded ring 39005 Show
Locking key for Ecoguss slotted gratings, Lock & Lift 67007 Show
Intake cage with push-fit fastener, for KTP 300 680013 Show
Seal O-ring for pressure pipe connection 680014 Show
One-handed closure for backflow preventer 680018 Show
Seal for pressure pipe connection 680067 Show
Cover tileable, Lock & Lift, ABS 680224 Show
Release key for Lock & Lift 680702 Show
Pressure pipe connection with seal and screws 680758 Show
Pressure pipe connection KTP 300 680759 Show
Pump connection Minilift, Aqualift S 680760 Show
Flap housing Mono, with pump connector 680761 Show
Turn fastener for pump connection lock 680762 Show
Seal for cover plate, System 330 mm 686114 Show
Seal Lip seal, System 330 mm 686115 Show
KESSEL cover pl, tileable drainage funct 830054 Show
  • Declaration of Performance (DOP) (ATTR-292): 009-082
  • Installation situation (ATTR-1): floor slab installation
  • Declaration of conformity (ATTR-303): 009-082-D
  • Country of origin (ATTR-322): DE
  • Area of application (ATTR-264): drainage
  • Pump type (ATTR-265): Freestanding pump
  • Pump shaft position (ATTR-266): vertical
  • Pump design (ATTR-267): Dry rotor pump
  • Pump hydraulics (ATTR-268): single stage
  • Pump suction characteristic (ATTR-269): non-self-priming
  • Pump drive (ATTR-270): E-motor for alternating current
  • E-motor, type of startup (ATTR-271): direct
  • Pump casing material (ATTR-272): Polymer
  • Motor pump shaft (ATTR-279): continuous
  • Shaft seal (ATTR-280): RSSR
  • Number of operating pumps (ATTR-281): 1
  • Minimum pumped media temperature (ATTR-282): 0  CEL
  • Maximum operating pressure (Pmax) (ATTR-283): 600  HPA
  • Minimum speed for speed adjustment (ATTR-284): no speed adjustment
  • Start-up current (ATTR-285): 3.8  AMP
  • Vertical installation (ATTR-286): yes
  • Pump (ATTR-4): KTP 300
  • Number of pumps (ATTR-181): 1
  • Impeller type (ATTR-8): Multi-vane impeller
  • Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.0 mm2
  • Type of fuse required (electrical protection) (ATTR-N3): C 16 A
  • Operating mode (ATTR-10): S1
  • Power P1 (ATTR-F4): 0.3  KWT
  • Power P2 (ATTR-F5): 0.2  KWT
  • Speed (ATTR-F2): 2,800  UMIN
  • Operating voltage (ATTR-131): 230  VLT
  • Mains frequency (ATTR-N4): 50  HTZ
  • Rated current (ATTR-N5): 1.6  AMP
  • Max. pumping capacity (ATTR-F7): 8  MQH
  • Max. pumping height (ATTR-F8): 6  MTR
  • Max. temperature (permanent) of conveyed material (ATTR-132): 40  CEL
  • Connection type (ATTR-N1): Schuko (earthed contact) 2-pin
  • Protection class (pump) (ATTR-125): IP 68 (3m)
  • Length of mains cable for pump (ATTR-11): 5  MTR
  • Temperature monitoring (ATTR-135): integrated
  • Net weight (ATTR-A3A): 10.8  KGM
  • Gross weight (ATTR-A3B): 11.7  KGM
  • Type of system (ATTR-2): Single station
  • Backflow preventer (ATTR-165): integrated
  • Pump control (ATTR-134): Float switch
  • Length (ATTR-A6A): 460  MMT
  • Width (ATTR-A6B): 380  MMT
  • Volume (ATTR-320): 0.1  MTQ
  • Packaging dimension: length (ATTR-325): 445  MMT
  • Packaging dimension: width (ATTR-326): 445  MMT
  • Packaging dimension: height (ATTR-327): 466  MMT
  • Dimensions (ATTR-323): 445X445X466MM
  • Number of packages (ATTR-321): 1
  • Inlet nominal size (DN) (ATTR-B1CA): 50  MMT
  • Installation depth (ATTR-B2_VB): 330  MMT
  • Pressure pipe connection (DN) (ATTR-B17): 32  MMT
  • Pressure pipe connection (OD) (ATTR-B18): 40  MMT
  • Pumping volume (ATTR-B10): 7  LTR
  • Type of cover (ATTR-A21): tileable cover plate
  • Colour of cover (ATTR-A2A): silver grey
  • Load class (ATTR-A2B): K 3 (EN 1253-1)
  • Locking (ATTR-A2D): Lock & Lift
  • Cover material (ATTR-A2E): Polymer
  • Max. flooring height (ATTR-A2L): 16  MMT
  • Length (ATTR-A2M): 366  MMT
  • Width (ATTR-A2N): 366  MMT
  • Wastewater quantity (ATTR-310): Low
  • Type of wastewater (ATTR-6): wastewater without sewage
  • Colour (ATTR-102): grey
  • Standard (ATTR-9): EN 12050-2
  • CE marking (ATTR-A5B): yes
  • Free passage (ATTR-180): 10  MMT
  • Delivery state (ATTR-189): Installation-ready (connection parts must be connected on site)
  • Brand (M-ATTR-001): KESSEL
  • Product group (M-ATTR-002): Lifting stations
  • Product type (M-ATTR-003): Lifting station
  • Product family (M-ATTR-004): Minilift
  • Product name (M-ATTR-005): Minilift S