Skip to main content

Lifting station Aqualift S 200

Duo, GTF 1250, Free-standing set-up

Lifting station for faecal-free wastewater, free-standing set-up, preassembled for final installation on site. - With odour-tight cover and quick-release closure for easy maintenance - Tank made of PE, resistant to aggressive wastewater - Including backflow preventer for the pressure pipe - Including socket DN 100 and DN 150 for inlet and sampling - Integrated sampling possibility - Pumps with multi-vane impeller for maximum operating reliability - Including control unit for recording level and alarm detection

  • 1. With odour-tight cover and quick-release closure for easy maintenance
  • 2. Tank made of PE, resistant to aggressive wastewater
  • 3. Including backflow preventer for the pressure pipe
Item no. 28518
GTIN 4026092092941
Price group 20

Lifting station Aqualift S 200 Duo, GTF 1250, Free-standing set-up
Lifting station for faecal-free wastewater, free-standing set-up, preassembled for final installation on site. - With odour-tight cover and quick-release closure for easy maintenance - Tank made of PE, resistant to aggressive wastewater - Including backflow preventer for the pressure pipe - Including socket DN 100 and DN 150 for inlet and sampling - Integrated sampling possibility - Pumps with multi-vane impeller for maximum operating reliability - Including control unit for recording level and alarm detection Type of wastewater: wastewater without sewage Installation situation: free-standing set-up Version: Type of system: Twin pump station Pump control: Control unit Backflow preventer: integrated Delivery state: Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected) General characteristics: Colour: black Standard: EN 12050-2 Dimensions: Length: 670 mm Width: 655 mm Height: 815 mm Tank: Inlet nominal size (DN): 100 Tank volume: 220 l Pumping volume: 100 l Pressure pipe connection (DN): 50 mm Pressure pipe connection (OD): 63 mm Coverage features: Type of cover: Cover Cover material: Polymer Colour of cover: violet Tightness: odour-tight Locking: Quick-release closure Free passage: 30 mm Pumping device: Pump: GTF 1250 Number of pumps: 2 Max. pumping capacity: 20 m3/h Max. pumping height: 11 m Operating voltage: 230 V Mains frequency: 50 Hz Operating mode: S1 Power P1: 1.3 kW Power P2: 0.8 kW Speed: 2,700 U/min Type of fuse required (electrical protection): C 16 A Max. temperature (permanent) of conveyed material: 40 °C Connection type: coded plug Weight: 10 kg Impeller type: Multi-vane impeller Length of mains cable for pump: 5 m Rated current: 5.4 A Protection class (pump): IP 68 (3m) Protection class: I Type of pump connection cable: H07RN-F 3G 1.0 mm2 Temperature monitoring: integrated Insulation class: F Control: Control unit: Comfort Operating voltage: 230 V Mains frequency: 50 Hz Self-diagnosis system (SDS): yes Battery buffering: yes Multi-line display: yes Log book function: yes USB interface: yes GSM interface: yes Potential-free contact: optional Motor protection switch: yes Protection class control unit: IP 54 Length of mains cable for control unit: 1.4 m Type of level measurement: pneumatic Alarm sensor: Immersion pipe
  Title Item no.  
  Title Item no.  
  Title Item no.  
Remote signal generator 20 m cable, 2x0.75 q 20162 Show
Retrofit kit Alarm float switch 28016 Show
Hole saw for DN 100/125/150 500100 Show
Hole saw for DN 50/70/100 500101 Show
Potential-free contact Additional circuit board for control units. 80072 Show
10 m probe cable extension set 80889 Show
Cable prolongation set for pump 10 m 80891 Show
Seal for pipe penetration, DN 50 850114 Show
Seal for channel passage 75 mm 850116 Show
Seal for channel passage 110 mm 850117 Show
Seal for pipe penetration, DN 125 850118 Show
Seal for pipe penetration, DN 150 850119 Show
  Title Item no.  
Control unit Aqualift Comfort 230 V Duo 28746 Show
One-handed closure for backflow preventer 680018 Show
Battery 9 V block 680034 Show
Seal for pressure pipe connection 680067 Show
Cover with seal 680076 Show
Seal for upper section, from 07/2014 680150 Show
Cover d: 420 mm, up to 03/2004 680326 Show
Pump connection with seal and flap 680475 Show
Pump connection Minilift, Aqualift S 680760 Show
Turn fastener for pump connection lock 680762 Show
Flap housing Duo, with pump connector 680781 Show
Multi-vane impeller for STF 1300 680804 Show
Pump hanger GTF 1250, Duo 680974 Show
Clamp fastener for cover 450 mm 680975 Show
Replacement pump GTF 1250 without float switch, 5 m 680979 Show
Dummy cover for Aqualift S 100/200 lifting station 680980 Show
Cable gland for Aqualift S 100/200 680981 Show
Inlet socket DN 100 for Aqualift S 100/200 680986 Show
Inlet socket DN 150 for Aqualift S 100/200 680987 Show
Immersion pipe for Aqualift S 100 lifting station 680988 Show
Sound absorption mat for Aqualift S 100 lifting station 680990 Show
Pressure pipe DN 32 for Aqualift S 200 GTF 600 680992 Show
Venting socket DN 70 for Aqualift S 200 680994 Show
Connector for Aqualift S 200 immersion pipe 680995 Show
Hose connection set for immersion pipes, Length 5 m 680996 Show
Seal DN65, for backflow preventer 680999 Show
  • Wastewater quantity (ATTR-310): Medium
  • Type of wastewater (ATTR-6): wastewater without sewage
  • Free passage (ATTR-180): 30  MMT
  • TÜV test mark (ATTR-376): ID 1111241937
  • Area of application (ATTR-264): drainage
  • Pump type (ATTR-265): submersible pump
  • Pump shaft position (ATTR-266): vertical
  • Pump design (ATTR-267): Dry rotor pump
  • Pump hydraulics (ATTR-268): single stage
  • Pump suction characteristic (ATTR-269): non-self-priming
  • Pump drive (ATTR-270): E-motor for alternating current
  • Pump casing material (ATTR-272): Polymer
  • Upper tolerance of the operating voltage (+) (ATTR-273): 10  PROZ
  • Lower tolerance of the operating voltage (-) (ATTR-274): 10  PROZ
  • Upper tolerance of the nominal frequency (+) (ATTR-275): 3  PROZ
  • Lower tolerance of the nominal frequency (-) (ATTR-276): 2  PROZ
  • Pump electrical connection (ATTR-277): 1/N/PE 230V
  • Startup circuit for three-phase connection or three-phase current (ATTR-278):
  • Motor pump shaft (ATTR-279): continuous
  • Shaft seal (ATTR-280): RSSR
  • Number of operating pumps (ATTR-281): 1
  • Minimum pumped media temperature (ATTR-282): 0  CEL
  • Maximum operating pressure (Pmax) (ATTR-283): 1,100  HPA
  • Minimum speed for speed adjustment (ATTR-284): no speed adjustment
  • Start-up current (ATTR-285): 14.9  AMP
  • Vertical installation (ATTR-286): yes
  • Pump (ATTR-4): GTF 1250
  • Number of pumps (ATTR-181): 2
  • Impeller type (ATTR-8): Multi-vane impeller
  • Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.0 mm2
  • Type of fuse required (electrical protection) (ATTR-N3): C 16 A
  • Operating mode (ATTR-10): S1
  • Power P1 (ATTR-F4): 1.3  KWT
  • Power P2 (ATTR-F5): 0.8  KWT
  • Speed (ATTR-F2): 2,700  UMIN
  • Operating voltage (ATTR-131): 230  VLT
  • Mains frequency (ATTR-N4): 50  HTZ
  • Rated current (ATTR-N5): 5.4  AMP
  • Max. pumping capacity (ATTR-F7): 20  MQH
  • Max. pumping height (ATTR-F8): 11  MTR
  • Max. temperature (permanent) of conveyed material (ATTR-132): 40  CEL
  • Protection class (ATTR-133): I
  • Connection type (ATTR-N1): coded plug
  • Length of mains cable for pump (ATTR-11): 5  MTR
  • Temperature monitoring (ATTR-135): integrated
  • Weight (ATTR-191): 10  KGM
  • Insulation class (ATTR-193): F
  • Type of system (ATTR-2): Twin pump station
  • Backflow preventer (ATTR-165): integrated
  • Pump control (ATTR-134): Control unit
  • Control unit (ATTR-S2): Comfort
  • Self-diagnosis system (SDS) (ATTR-S5): yes
  • Battery buffering (ATTR-S6): yes
  • Multi-line display (ATTR-S7): yes
  • Log book function (ATTR-S8): yes
  • USB interface (ATTR-S9): yes
  • GSM interface (ATTR-S10): yes
  • Potential-free contact (ATTR-S11): optional
  • Length of mains cable for control unit (ATTR-S12): 1.4  MTR
  • Operating voltage (ATTR-S13): 230  VLT
  • Mains frequency (ATTR-S14): 50  HTZ
  • Protection class control unit (ATTR-S4): IP 54
  • Alarm sensor (ATTR-S1): Immersion pipe
  • Type of level measurement (ATTR-7A): pneumatic
  • Motor protection switch (ATTR-172): yes
  • - (ATTR-S21):
  • - (ATTR-S22):
  • - (ATTR-S23):
  • Inlet nominal size (DN) (ATTR-B1CA): 100  MMT
  • Pressure pipe connection (DN) (ATTR-B17): 50  MMT
  • Pressure pipe connection (OD) (ATTR-B18): 63  MMT
  • Tank volume (ATTR-B9): 220  LTR
  • Pumping volume (ATTR-B10): 100  LTR
  • Type of cover (ATTR-A21): Cover
  • Colour of cover (ATTR-A2A): violet
  • Tightness (ATTR-A2C): odour-tight
  • Locking (ATTR-A2D): Quick-release closure
  • Cover material (ATTR-A2E): Polymer
  • Length (ATTR-A6A): 670  MMT
  • Width (ATTR-A6B): 655  MMT
  • Height (ATTR-A6C): 815  MMT
  • Volume (ATTR-320): 0.8  MTQ
  • Packaging dimension: length (ATTR-325): 900  MMT
  • Packaging dimension: width (ATTR-326): 900  MMT
  • Packaging dimension: height (ATTR-327): 939  MMT
  • Dimensions (ATTR-323): 900X900X939MM
  • Number of packages (ATTR-321): 1
  • Installation situation (ATTR-1): free-standing set-up
  • Declaration of Performance (DOP) (ATTR-292): 009-210
  • Declaration of conformity (ATTR-303): 009-210-D
  • Colour (ATTR-102): black
  • Standard (ATTR-9): EN 12050-2
  • CE marking (ATTR-A5B): yes
  • Delivery state (ATTR-189): Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected)
  • Brand (M-ATTR-001): KESSEL
  • Product group (M-ATTR-002): Lifting stations
  • Product type (M-ATTR-003): Lifting station
  • Product family (M-ATTR-004): Aqualift
  • Product name (M-ATTR-005): Aqualift S
  • - (ATTR-370):
  • Protection class (pump) (ATTR-125): IP 68 (3m)