Lifting station Aqualift F Mono

Mono, Standard, SPF 1500-S3, Gate valve

The lifting station for faecal and faecal-free wastewater is equipped with a submersible pump and a backflow preventer. The collection tank made of permanently resistant polymer (PE) offers universal connection options and has a screwed access cover. The station is controlled by a user-friendly control unit, which can be optionally integrated in the building management system via a potential-free contact or alarm and collective fault messages can be output via a GSM interface (Comfort control unit).

  • Different performance classes available
  • Pressure sensor for reliable pneumatic level measurement
  • Including sound absorption mat
Item no. 28644
GTIN 4026092007693
Price group 20

Lifting station Aqualift F Mono Mono, Standard, SPF 1500-S3, Gate valve
The lifting station for faecal and faecal-free wastewater is equipped with a submersible pump and a backflow preventer. The collection tank made of permanently resistant polymer (PE) offers universal connection options and has a screwed access cover. The station is controlled by a user-friendly control unit, which can be optionally integrated in the building management system via a potential-free contact or alarm and collective fault messages can be output via a GSM interface (Comfort control unit). Type of wastewater: wastewater with sewage Installation situation: free-standing set-up Version: Type of system: Single station Shut-off valve: Shut-off valve made of polymer Pump control: Control unit Backflow preventer: integrated Sound absorption mat: yes Delivery state: Installation-ready (electrical components, connection parts must be connected on site) General characteristics: Colour: black Standard: EN 12050-1 Dimensions: Length: 564 mm Width: 525 mm Height: 664 mm Tank: Number of inlets: 1 ST Inlet nominal size (DN): 100 Inlet nominal size (OD): 110 mm Inlet max. scoring (DN): 150 mm Distance pipe bottom inlet to tank bottom: 125 mm Distance from centre of outlet pipe to tank bottom: 466 mm Distance from centre of inlet pipe to tank bottom: 180 mm Connection for manual diaphragm pump (DN): 32 Tank volume: 50 l Pumping volume: 20 l Pressure pipe connection: horizontal Pressure pipe connection (DN): 100 mm Pressure pipe connection (OD): 110 mm Venting connection (DN): 70 mm Free passage: 40 mm Pumping device: Pump: SPF 1500 Number of pumps: 1 Max. pumping capacity: 40 m3/h Max. pumping height: 8 m Operating mode: S3 - 50 % Power P1: 1.4 kW Power P2: 1.1 kW Speed: 1,415 U/min Max. temperature (permanent) of conveyed material: 40 °C Connection type: Direct connection Weight: 24 kg Impeller type: Multi-vane impeller Length of mains cable for pump: 5 m Rated current: 2.7 A Protection class (pump): IP 68 (3m/48h) Protection class: I Type of pump connection cable: H07RN-F 7G 1.5 mm2 Temperature monitoring: integrated Cos phi - power factor: 0.77 Insulation class: F Control: Control unit: Standard Operating voltage: 400 V Mains frequency: 50 Hz Self-diagnosis system (SDS): yes Battery buffering: yes Multi-line display: no Log book function: yes Potential-free contact: yes Type of fuse required (electrical protection): 3 x C 16 A Motor protection switch: yes Protection class control unit: IP 54 Length of mains cable for control unit: 0 m Type of level measurement: pneumatic Level measurement instrument: Immersion pipe Alarm sensor: Immersion pipe

Installation Video

  Title Item no.  
  Title Item no.  
  Title Item no.  
Remote signal generator 20 m cable, 2x0.75 q 20162 Show
Retrofit kit Alarm float switch, Aqualift F and F Duo 28015 Show
Compressor set for air bubbling 28048 Show
Flexible coupling DN 80, L: 200 mm 28662 Show
Elastic union joint for hoses Ø 110 28663 Show
Shut-off valve DN 80, Polymer, horizontal 28682 Show
Shut-off valve DN 100, Polymer, horizontal 28683 Show
Shut-off valve DN 100, Polymer 28698 Show
Shut-off valve DN 150, Polymer 28699 Show
Flange joint DN 100, for polymer fittings 28712 Show
Flange joint DN 80, for polymer fittings 28713 Show
Flange adapter DN 80, for polymer fitting 28714 Show
Shut-off valve DN 80, Polymer, vert 28715 Show
Shut-off valve DN 80, Polymer, vertical with flange 28716 Show
TeleControl GSM modem for Comfort control units 230V/400V 28792 Show
  Title Item no.  
Pump motor SPF 1500 / 400 V S3 28028 Show
Pressure switch Mono 28045 Show
Replacement set pump flange 28051 Show
Gasket set fro pressure switch 28608 Show
Elastic union joint for hoses Ø 110 28663 Show
Replacement set Mono flap housing 28676 Show
Shut-off valve DN 100, Polymer, horizontal 28683 Show
Flange adapter DN 80, for polymer fitting 28714 Show
Battery 9 V block 680034 Show
Cleaning cover screwed, 160x140 mm 680044 Show
Seal Pump flange 680045 Show
Attachment bracket with screws (2 ea.) 680046 Show
Screw set galvanised, 14 each 680047 Show
Immersion pipe Mono, 10 m cable 680048 Show
Pump flange SPF 1400 - SPF 4500 680050 Show
Seal for SPF 1400 - SPF 4500 680052 Show
Flap set Rolling ring, flap, flap holder 680053 Show
Immersion pipe Mono, 5 m hose 680055 Show
Flap housing for Mono systems, without shut-off valve 680060 Show
Impeller SPF 1400/1500, Aqualift lifting stations 680643 Show
  • TÜV test mark (ATTR-376): ID 1111241940
  • Country of origin (ATTR-322): DE
  • Area of application (ATTR-264): drainage
  • Pump type (ATTR-265): Freestanding pump
  • Pump shaft position (ATTR-266): vertical
  • Pump design (ATTR-267): Dry rotor pump
  • Pump hydraulics (ATTR-268): single stage
  • Pump suction characteristic (ATTR-269): non-self-priming
  • Pump drive (ATTR-270): E-motor for three-phase current
  • E-motor, type of startup (ATTR-271): direct
  • Pump casing material (ATTR-272): Grey iron
  • Upper tolerance of the operating voltage (+) (ATTR-273): 10  PROZ
  • Lower tolerance of the operating voltage (-) (ATTR-274): 10  PROZ
  • Upper tolerance of the nominal frequency (+) (ATTR-275): 3  PROZ
  • Lower tolerance of the nominal frequency (-) (ATTR-276): 2  PROZ
  • Pump electrical connection (ATTR-277): 3/N/PE 400V
  • Startup circuit for three-phase connection or three-phase current (ATTR-278): Star
  • Motor pump shaft (ATTR-279): continuous
  • Shaft seal (ATTR-280): RSSR
  • Number of operating pumps (ATTR-281): 1
  • Minimum pumped media temperature (ATTR-282): 0  CEL
  • Maximum operating pressure (Pmax) (ATTR-283): 800  HPA
  • Minimum speed for speed adjustment (ATTR-284): no speed adjustment
  • Start-up current (ATTR-285): 21  AMP
  • Vertical installation (ATTR-286): yes
  • Pump (ATTR-4): SPF 1500
  • Number of pumps (ATTR-181): 1
  • Impeller type (ATTR-8): Multi-vane impeller
  • Type of pump connection cable (ATTR-N2): H07RN-F 7G 1.5 mm2
  • Max. permissible switching frequency (ATTR-162): 20  1PH
  • Operating mode (ATTR-10): S3 - 50 %
  • Power P1 (ATTR-F4): 1.4  KWT
  • Power P2 (ATTR-F5): 1.1  KWT
  • Speed (ATTR-F2): 1,415  UMIN
  • Rated current (ATTR-N5): 2.7  AMP
  • Max. pumping capacity (ATTR-F7): 40  MQH
  • Max. pumping height (ATTR-F8): 8  MTR
  • Max. temperature (permanent) of conveyed material (ATTR-132): 40  CEL
  • Protection class (ATTR-133): I
  • Connection type (ATTR-N1): Direct connection
  • Protection class (pump) (ATTR-125): IP 68 (3m/48h)
  • Length of mains cable for pump (ATTR-11): 5  MTR
  • Temperature monitoring (ATTR-135): integrated
  • Weight (ATTR-191): 24  KGM
  • Cos phi - power factor (ATTR-192): 0.8
  • Insulation class (ATTR-193): F
  • Expected service life (hours of operation) (ATTR-194): 5,000  HUR
  • Expected service life (number of switching cycles) (ATTR-195): 150,000
  • Length (ATTR-A6A): 564  MMT
  • Width (ATTR-A6B): 525  MMT
  • Height (ATTR-A6C): 664  MMT
  • Volume (ATTR-320): 0.2  MTQ
  • Packaging dimension: length (ATTR-325): 645  MMT
  • Packaging dimension: width (ATTR-326): 530  MMT
  • Packaging dimension: height (ATTR-327): 570  MMT
  • Dimensions (ATTR-323): 645X530X570MM
  • Number of packages (ATTR-321): 1
  • Shut-off valve (ATTR-A1): Shut-off valve made of polymer
  • Pressure pipe connection (ATTR-B7): horizontal
  • Type of system (ATTR-2): Single station
  • Backflow preventer (ATTR-165): integrated
  • Pump control (ATTR-134): Control unit
  • Sound absorption mat (ATTR-185): yes
  • Retaining bracket for the lift protection (ATTR-186): yes
  • Control unit (ATTR-S2): Standard
  • Self-diagnosis system (SDS) (ATTR-S5): yes
  • Battery buffering (ATTR-S6): yes
  • Multi-line display (ATTR-S7): no
  • Log book function (ATTR-S8): yes
  • Potential-free contact (ATTR-S11): yes
  • Length of mains cable for control unit (ATTR-S12): 0  MTR
  • Operating voltage (ATTR-S13): 400  VLT
  • Mains frequency (ATTR-S14): 50  HTZ
  • Protection class control unit (ATTR-S4): IP 54
  • Alarm sensor (ATTR-S1): Immersion pipe
  • Type of level measurement (ATTR-7A): pneumatic
  • Level measurement instrument (ATTR-7B): Immersion pipe
  • Type of fuse required (electrical protection) (ATTR-S17): 3 x C 16 A
  • Motor protection switch (ATTR-172): yes
  • Number of inlets (ATTR-B1B): 1  PCE
  • Inlet nominal size (DN) (ATTR-B1CA): 100  MMT
  • Inlet nominal size (OD) (ATTR-B1CB): 110  MMT
  • Distance from centre of inlet pipe to tank bottom (ATTR-B6): 180  MMT
  • Distance pipe bottom inlet to tank bottom (ATTR-B1D): 125  MMT
  • Inlet max. scoring (DN) (ATTR-B1E): 150  MMT
  • Distance from centre of outlet pipe to tank bottom (ATTR-B15E): 466  MMT
  • Venting connection (DN) (ATTR-B4): 70  MMT
  • Connection for manual diaphragm pump (DN) (ATTR-B4B): 32
  • Pressure pipe connection (DN) (ATTR-B17): 100  MMT
  • Pressure pipe connection (OD) (ATTR-B18): 110  MMT
  • Tank volume (ATTR-B9): 50  LTR
  • Pumping volume (ATTR-B10): 20  LTR
  • Reaction to fire (ATTR-306): Class E to EN 13501-1
  • Standard (ATTR-9): EN 12050-1
  • CE marking (ATTR-A5B): yes
  • Installation situation (ATTR-1): free-standing set-up
  • Free passage (ATTR-180): 40  MMT
  • Delivery state (ATTR-189): Installation-ready (electrical components, connection parts must be connected on site)
  • Declaration of Performance (DOP) (ATTR-292): 009-011
  • Wastewater quantity (ATTR-310): Medium
  • Type of wastewater (ATTR-6): wastewater with sewage
  • Declaration of conformity (ATTR-303): 009-011-D
  • Colour (ATTR-102): black
  • External monitoring (ATTR-A8): LGA
  • Brand (M-ATTR-001): KESSEL
  • Product group (M-ATTR-002): Lifting stations
  • Product type (M-ATTR-003): Lifting station
  • Product family (M-ATTR-004): Aqualift
  • Product name (M-ATTR-005): Aqualift F