Skip to main content

Backwater valve StaufixControl

DN 100, exposed, Type 2 R

The backwater valve for wastewater without sewage is equipped with two mechanical flaps which close automatically in the event of backwater. One flap serves at the same time as an emergency closure to be closed by hand. The battery-operated warning unit in the lockable cover generates an optical and acoustic warning if backwater occurs. Optionally, the warning message can control a remote signal generator in the living area via the EnOcean protocol or automatically disconnect a switched socket from the mains.

  • optical and acoustic warning message if backwater occurs
  • Wireless backwater signal (EnOcean) can be integrated in the control system
  • Flexible installation, various covers available for floor slab installation
Item no. 770100R
GTIN 4026092076682
Price group 10

Backwater valve StaufixControl DN 100, exposed, Type 2 R
The backwater valve for wastewater without sewage is equipped with two mechanical flaps which close automatically in the event of backwater. One flap serves at the same time as an emergency closure to be closed by hand. The battery-operated warning unit in the lockable cover generates an optical and acoustic warning if backwater occurs. Optionally, the warning message can control a remote signal generator in the living area via the EnOcean protocol or automatically disconnect a switched socket from the mains. Type of wastewater: wastewater without sewage Installation situation: exposed drainage pipe Version: Stainless steel flap as rat protection: yes Emergency closure: yes Delivery state: installation-ready Backwater protection: Type 2 Number of mechanical backwater flaps: 2 General characteristics: Nominal size (DN): 100 Outer diameter (OD): 110 Colour: black Standard: EN 13564 Dimensions: Length: 389 mm Width: 167 mm Height: 230 mm Coverage features: Type of cover: Lockable cover Vertical drop between inlet and outlet: 8 mm Control: Type of level measurement: pneumatic Level measurement instrument: Pressure switch Cover locking: One-handed closure

Installation Video

  Title Item no.  
  Title Item no.  
  Title Item no.  
Remote signal generator for optical/acoustic. signal in the event of backwater 72222 Show
Radio receiver as switched socket 72223 Show
  Title Item no.  
Test hose for control unit 680668 Show
Seal Cover seal for Staufix DN 90-110 686112 Show
Staufix test funnel with seal 70214 Show
Polymer backwater flap Ø 100/110 70231 Show
Backwater flap, DN100, f. Staufix/Contro 70233 Show
Flap housing with gasket Ø 100/110 70241 Show
StaufixContr. lockable cover DN 90-100 72224 Show
Spigot DN 100 830100 Show
Socket DN 100 830101 Show
  • Backwater protection (ATTR-151): Type 2
  • Installation situation (ATTR-1): exposed drainage pipe
  • Country of origin (ATTR-322): DE
  • Cover locking (ATTR-117): One-handed closure
  • Nominal size (DN) (ATTR-118): 100
  • Outer diameter (OD) (ATTR-147): 110
  • Delivery state (ATTR-189): installation-ready
  • Connection to the BCS, BAC (ATTR-257): yes
  • Length (ATTR-A6A): 389  MMT
  • Width (ATTR-A6B): 167  MMT
  • Height (ATTR-A6C): 230  MMT
  • Volume (ATTR-320): 0.0  MTQ
  • Packaging dimension: length (ATTR-325): 386  MMT
  • Packaging dimension: width (ATTR-326): 163  MMT
  • Packaging dimension: height (ATTR-327): 198  MMT
  • Dimensions (ATTR-323): 386X163X198MM
  • Number of packages (ATTR-321): 1
  • Type of cover (ATTR-A21): Lockable cover
  • Emergency closure (ATTR-153): yes
  • Stainless steel flap as rat protection (ATTR-155): yes
  • Type of level measurement (ATTR-7A): pneumatic
  • Level measurement instrument (ATTR-7B): Pressure switch
  • Net weight (ATTR-A3A): 1.5  KGM
  • Gross weight (ATTR-A3B): 4.1  KGM
  • Standard (ATTR-9): EN 13564
  • CE marking (ATTR-A5B): yes
  • Number of mechanical backwater flaps (ATTR-154): 2
  • External monitoring (ATTR-A8): LGA
  • Declaration of Performance (DOP) (ATTR-292): 009-051
  • Protection strategy (ATTR-311): Central protection
  • Type of wastewater (ATTR-6): wastewater without sewage
  • Position relative to sewer (ATTR-309): Gradient to the sewer
  • Function in the event of backwater (ATTR-312): Protects in the event of backwater
  • Colour (ATTR-102): black
  • Note on type of wastewater (ATTR-187): Country-specific regulations related to the area of application can deviate
  • Vertical drop between inlet and outlet (ATTR-176): 8  MMT
  • Declaration of conformity (ATTR-303): 009-583
  • Brand (M-ATTR-001): KESSEL
  • Product group (M-ATTR-002): Backwater valves
  • Product type (M-ATTR-003): Backwater valve
  • Product family (M-ATTR-004): Staufix
  • Product name (M-ATTR-005): StaufixControl