Pumpfix F conversion kit
DN 100-200, fr. 01/2012, 15 m cable
The conversion kit is equipped with a pump and a motor-driven closure system. The pipe cross-section is normally open. In case of backwater, the motor-driven closure system is closed automatically. During the backwater phase, the water drains via the pump with integrated macerator. The station is controlled by a user-friendly control unit, which is optionally integrated in the building management system via a potential-free contact, or alarm and collective fault messages can be output via a GSM interface. The conversion kit is used to upgrade backwater chambers LW 1000 and backwater module chambers LW 1000 with the Pumpfix F backwater pumping station.
Item no. | 80102 |
---|---|
GTIN | 4026092051160 |
Price group | 30 |
Pumpfix F conversion kit DN 100-200, fr. 01/2012, 15 m cable
The conversion kit is equipped with a pump and a motor-driven closure system. The pipe cross-section is normally open. In case of backwater, the motor-driven closure system is closed automatically. During the backwater phase, the water drains via the pump with integrated macerator. The station is controlled by a user-friendly control unit, which is optionally integrated in the building management system via a potential-free contact, or alarm and collective fault messages can be output via a GSM interface. The conversion kit is used to upgrade backwater chambers LW 1000 and backwater module chambers LW 1000 with the Pumpfix F backwater pumping station. Type of wastewater: wastewater with and without sewage General characteristics: Nominal size (DN): 100-200 Note on nominal size: Hydraulics correspond to DN 150 Approval: Z-53.2-388 Pumping device: Pump: SPZ 1000 Number of pumps: 1 Max. pumping capacity: 11.5 m3/h Max. pumping height: 10 m Operating mode: S3 - 50 % Power P1: 1.2 kW Power P2: 0.69 kW Speed: 2,800 U/min Type of fuse required (electrical protection): C 16 A Max. temperature (permanent) of conveyed material: 35 °C Connection type: coded plug Weight: 10 kg Impeller type: Macerator Rated current: 5.2 A Protection class (pump): IP 68 (3m/48h) Protection class: I Type of pump connection cable: H07RN-F 3G 1.0 mm2 Temperature monitoring: integrated Cos phi - power factor: 0.97 Insulation class: F Cable length: 15 m Control: Control unit: Comfort Operating voltage: 230 V Mains frequency: 50 Hz Self-diagnosis system (SDS): yes Battery buffering: yes Multi-line display: yes Log book function: yes USB interface: yes GSM interface: yes Potential-free contact: optional Protection class control unit: IP 54 Length of mains cable for control unit: 1.4 m Type of level measurement: optical Level measurement instrument: optical probe Alarm sensor: optical probe
Title | Item no. |
---|
Title | Item no. |
---|
Title | Item no. |
---|
Title | Item no. |
---|
- Type of wastewater (ATTR-6): wastewater with and without sewage
- Approval (ATTR-A5): Z-53.2-388
- Cable length (ATTR-190): 15 MTR
- Pump (ATTR-4): SPZ 1000
- Number of pumps (ATTR-181): 1
- Impeller type (ATTR-8): Macerator
- Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.0 mm2
- Type of fuse required (electrical protection) (ATTR-N3): C 16 A
- Max. permissible switching frequency (ATTR-162): 20 1PH
- Operating mode (ATTR-10): S3 - 50 %
- Power P1 (ATTR-F4): 1.2 KWT
- Power P2 (ATTR-F5): 0.7 KWT
- Speed (ATTR-F2): 2,800 UMIN
- Rated current (ATTR-N5): 5.2 AMP
- Max. pumping capacity (ATTR-F7): 11.5 MQH
- Max. pumping height (ATTR-F8): 10 MTR
- Max. temperature (permanent) of conveyed material (ATTR-132): 35 CEL
- Protection class (ATTR-133): I
- Connection type (ATTR-N1): coded plug
- Protection class (pump) (ATTR-125): IP 68 (3m/48h)
- Temperature monitoring (ATTR-135): integrated
- Weight (ATTR-191): 10 KGM
- Cos phi - power factor (ATTR-192): 1.0
- Insulation class (ATTR-193): F
- Expected service life (hours of operation) (ATTR-194): 5,000 HUR
- Expected service life (number of switching cycles) (ATTR-195): 150,000
- Brand (M-ATTR-001): KESSEL
- Nominal size (DN) (ATTR-118): 100-200
- Note on nominal size (ATTR-118B): Hydraulics correspond to DN 150
- Net weight (ATTR-A3A): 21.3 KGM
- Gross weight (ATTR-A3B): 23.1 KGM
- Control unit (ATTR-S2): Comfort
- Self-diagnosis system (SDS) (ATTR-S5): yes
- Battery buffering (ATTR-S6): yes
- Multi-line display (ATTR-S7): yes
- Log book function (ATTR-S8): yes
- USB interface (ATTR-S9): yes
- GSM interface (ATTR-S10): yes
- Potential-free contact (ATTR-S11): optional
- Length of mains cable for control unit (ATTR-S12): 1.4 MTR
- Operating voltage (ATTR-S13): 230 VLT
- Mains frequency (ATTR-S14): 50 HTZ
- Protection class control unit (ATTR-S4): IP 54
- Alarm sensor (ATTR-S1): optical probe
- Type of level measurement (ATTR-7A): optical
- Level measurement instrument (ATTR-7B): optical probe