Pumping station Aquapump F XL
Duo, SPF 1400-S3
The pumping station for faecal and faecal-free wastewater is equipped with a submersible pump, a backflow preventer and a shut-off valve for the pressure pipe. The collection tank made of permanently resistant polymer (PE) has a closed pump tank (dry installation) with a screwed-on access cover. The station is controlled by a user-friendly control unit, which is optionally integrated in the building management system via a potential-free contact. Alternatively, alarm and collective fault messages can be output via a GSM interface. The KESSEL modular system provides different upper sections and engineering chamber options as accessories.
- Maximum safety
- Flexible installation
- Hygienic advantages for maintenance and repair
Item no. | 8742004 |
---|---|
GTIN | 4026092068595 |
Price group | 60 |
Pumping station Aquapump F XL Duo, SPF 1400-S3
The pumping station for faecal and faecal-free wastewater is equipped with a submersible pump, a backflow preventer and a shut-off valve for the pressure pipe. The collection tank made of permanently resistant polymer (PE) has a closed pump tank (dry installation) with a screwed-on access cover. The station is controlled by a user-friendly control unit, which is optionally integrated in the building management system via a potential-free contact. Alternatively, alarm and collective fault messages can be output via a GSM interface. The KESSEL modular system provides different upper sections and engineering chamber options as accessories. Type of wastewater: wastewater with sewage Installation situation: underground installation, floor slab installation Version: Type of system: Twin pump station Installation: Dry installation Shut-off valve: Shut-off valve made of polymer Pump control: Control unit Backflow preventer: integrated Access steps: yes Note on installation depth: Version for deeper installation, in combination with a chamber module Delivery state: Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected) General characteristics: Colour: black Standard: EN 12050-1 Dimensions: Length: 1,295 mm Width: 1,295 mm Height: 1,403 mm Tank: Number of inlets: 1 ST Inlet nominal size (DN): 150 Inlet nominal size (OD): 160 mm Distance pipe bottom inlet to tank bottom: 753 mm Distance from centre of outlet pipe to tank bottom: 1,300 mm Distance from centre of inlet pipe to tank bottom: 833 mm Tank volume: 335 l Pumping volume: 160 l Pressure pipe connection: horizontal Pressure pipe connection (DN): 80 mm Pressure pipe connection (OD): 90 mm Venting connection (DN): 70 mm Groundwater resistant from lower edge of base section: 3,000 mm Clear width of tank (LW): 1,000 mm Free passage: 40 mm Pumping device: Pump: SPF 1400 Number of pumps: 2 Max. pumping capacity: 38 m3/h Max. pumping height: 7 m Operating mode: S3 - 50 % Power P1: 1.6 kW Power P2: 1.1 kW Speed: 1,370 U/min Max. temperature (permanent) of conveyed material: 40 °C Connection type: coded plug Weight: 25 kg Impeller type: Multi-vane impeller Length of mains cable for pump: 10 m Rated current: 7.3 A Protection class (pump): IP 68 (3m/48h) Protection class: I Type of pump connection cable: H07RN-F 3G 1.5 mm2 Temperature monitoring: integrated Cos phi - power factor: 0.98 Insulation class: F Control: Control unit: Comfort Operating voltage: 230 V Mains frequency: 50 Hz Self-diagnosis system (SDS): yes Battery buffering: yes Multi-line display: yes Log book function: yes USB interface: yes GSM interface: yes Potential-free contact: optional Type of fuse required (electrical protection): C 16 A Protection class control unit: IP 54 Length of mains cable for control unit: 1.4 m Type of level measurement: pneumatic Level measurement instrument: Immersion pipe Alarm sensor: Immersion pipe
Installation Video
Title | Item no. | ||
---|---|---|---|
Chamber module LW 1000 ground Access LW 800, 411-660 mm, Class K 3 | 8740002 | Show | |
Chamber module LW 1000 floor slab Access LW 800, 668-917 mm, Class K 3 | 8740003 | Show | |
Chamber module LW 1000 ground Access LW 800, 396-645 mm, Class A 15 | 8740004 | Show | |
Chamber module LW 1000 floor slab Access LW 800, 653-902 mm, Class L 15 | 8740005 | Show | |
Chamber module LW 1000 ground Access LW 800, 661-910 mm, Class K 3 | 8740008 | Show | |
Chamber module LW 1000 floor slab Access LW 800, 918-1167 mm, Class K 3 | 8740009 | Show | |
Chamber module LW 1000 ground Access LW 800, 646-895 mm, Class A 15 | 8740010 | Show | |
Chamber module LW 1000 floor slab Access LW 800, 903-1152 mm, Class L 15 | 8740011 | Show | |
Chamber module LW 1000 ground Access LW 800, 911-1160 mm, Class K 3 | 8740014 | Show | |
Chamber module LW 1000 floor slab Access LW 800, 1168-1417 mm, Class K 3 | 8740015 | Show | |
Chamber module LW 1000 ground Access LW 800, 896-1145 mm, Class A 15 | 8740016 | Show | |
Chamber module LW 1000 floor slab Access LW 800, 1153-1402 mm, Class L 15 | 8740017 | Show | |
Chamber module LW 1000 ground Access LW 600, 1130-1379 mm, Class A/B | 8740018 | Show | |
Chamber module LW 1000 ground Access LW 600, 1130-1379 mm, Class D | 8740019 | Show | |
Chamber module LW 1000 ground Access LW 800, 1161-1410 mm, Class K 3 | 8740020 | Show | |
Chamber module LW 1000 floor slab Access LW 800, 1418-1667 mm, Class K 3 | 8740021 | Show | |
Chamber module LW 1000 ground Access LW 800, 1146-1395 mm, Class A 15 | 8740022 | Show | |
Chamber module LW 1000 floor slab Access LW 800, 1403-1652 mm, Class L 15 | 8740023 | Show | |
Chamber module LW 1000 ground Access LW 600, 1380-1629 mm, Class A/B | 8740024 | Show | |
Chamber module LW 1000 ground Access LW 600, 1380-1629 mm, Class D | 8740025 | Show | |
Chamber module LW 1000 ground Access LW 800, 1411-1660 mm, Class K 3 | 8740026 | Show | |
Chamber module LW 1000 floor slab Access LW 800, 1668-1917 mm, Class K 3 | 8740027 | Show | |
Chamber module LW 1000 ground Access LW 800, 1396-1645 mm, Class A 15 | 8740028 | Show | |
Chamber module LW 1000 floor slab Access LW 800, 1653-1902 mm, Class L 15 | 8740029 | Show | |
Chamber module LW 1000 ground Access LW 600, 1630-1879 mm, Class A/B | 8740030 | Show | |
Chamber module LW 1000 ground Access LW 600, 1630-1879 mm, Class D | 8740031 | Show | |
Chamber module LW 1000 ground Access LW 800, 1661-1910 mm, Class K 3 | 8740032 | Show | |
Chamber module LW 1000 ground Access LW 800, 1646-1895 mm, Class A 15 | 8740034 | Show | |
Chamber module LW 1000 ground Access LW 600, 1880-2129 mm, Class A/B | 8740036 | Show | |
Chamber module LW 1000 ground Access LW 600, 1880-2129 mm, Class D | 8740037 | Show | |
Chamber module LW 1000 ground Access LW 800, 1911-2160 mm, Class K 3 | 8740038 | Show | |
Chamber module LW 1000 ground Access LW 800, 1896-2145 mm, Class A 15 | 8740040 | Show | |
Chamber module LW 1000 ground Access LW 600, 2130-2379 mm, Class A/B | 8740042 | Show | |
Chamber module LW 1000 ground Access LW 600, 2130-2379 mm, Class D | 8740043 | Show | |
Chamber module LW 1000 ground Access LW 800, 2161-2410 mm, Class K 3 | 8740044 | Show | |
Chamber module LW 1000 ground Access LW 800, 2146-2395 mm, Class A 15 | 8740046 | Show | |
Chamber module LW 1000 ground Access LW 600, 2380-2629 mm, Class A/B | 8740048 | Show | |
Chamber module LW 1000 ground Access LW 600, 2380-2629 mm, Class D | 8740049 | Show | |
Chamber module LW 1000 ground Access LW 800, 2411-2660 mm, Class K 3 | 8740050 | Show | |
Chamber module LW 1000 ground Access LW 800, 2396-2645 mm, Class A 15 | 8740052 | Show | |
Chamber module LW 1000 ground Access LW 600, 2630-2879 mm, Class A/B | 8740054 | Show | |
Chamber module LW 1000 ground Access LW 600, 2630-2879 mm, Class D | 8740055 | Show | |
Chamber module LW 1000 ground Access LW 800, 2661-2910 mm, Class K 3 | 8740056 | Show | |
Chamber module LW 1000 ground Access LW 800, 2646-2895 mm, Class A 15 | 8740058 | Show | |
Chamber module LW 1000 ground Access LW 600, 2880-3129 mm, Class A/B | 8740060 | Show | |
Chamber module LW 1000 ground Access LW 600, 2880-3129 mm, Class D | 8740061 | Show | |
Chamber module LW 1000 ground Access LW 800, 2911-3160 mm, Class K 3 | 8740062 | Show | |
Chamber module LW 1000 ground Access LW 800, 2896-3145 mm, Class A 15 | 8740064 | Show | |
Chamber module LW 1000 ground Access LW 600, 3130-3379 mm, Class A/B | 8740066 | Show | |
Chamber module LW 1000 ground Access LW 600, 3130-3379 mm, Class D | 8740067 | Show | |
Chamber module LW 1000 ground Access LW 800, 3161-3410 mm, Class K 3 | 8740068 | Show | |
Chamber module LW 1000 ground Access LW 800, 3146-3395 mm, Class A 15 | 8740070 | Show | |
Chamber module LW 1000 ground Access LW 600, 3380-3629 mm, Class A/B | 8740072 | Show | |
Chamber module LW 1000 ground Access LW 600, 3380-3629 mm, Class D | 8740073 | Show | |
Chamber module LW 1000 ground Access LW 800, 3411-3660 mm, Class K 3 | 8740074 | Show | |
Chamber module LW 1000 ground Access LW 800, 3396-3645 mm, Class A 15 | 8740076 | Show | |
Chamber module LW 1000 ground Access LW 600, 3630-3879 mm, Class A/B | 8740078 | Show | |
Chamber module LW 1000 ground Access LW 600, 3630-3879 mm, Class D | 8740079 | Show | |
Chamber module LW 1000 ground Access LW 800, 3661-3910 mm, Class K 3 | 8740080 | Show | |
Chamber module LW 1000 ground Access LW 800, 3646-3895 mm, Class A 15 | 8740082 | Show | |
Chamber module LW 1000 ground Access LW 600, 3880-4129 mm, Class A/B | 8740084 | Show | |
Chamber module LW 1000 ground Access LW 600, 3880-4129 mm, Class D | 8740085 | Show | |
Chamber module LW 1000 ground Access LW 800, 3911-4160 mm, Class K 3 | 8740086 | Show | |
Chamber module LW 1000 ground Access LW 800, 3896-4145 mm, Class A 15 | 8740088 | Show | |
Chamber module LW 1000 ground Access LW 800, 375-624 mm, Class K 3 | 8740122 | Show | |
Chamber module LW 1000 ground Access LW 800, 625-874 mm, Class K 3 | 8740123 | Show | |
Chamber module LW 1000 ground Access LW 800, 875-1124 mm, Class K 3 | 8740124 | Show | |
Chamber module LW 1000 ground Access LW 800, 1125-1374 mm, Class K 3 | 8740125 | Show | |
Chamber module LW 1000 ground Access LW 800, 1375-1624 mm, Class K 3 | 8740126 | Show | |
Chamber module LW 1000 ground Access LW 800, 1625-1874 mm, Class K 3 | 8740127 | Show | |
Chamber module LW 1000 ground Access LW 800, 1875-2124 mm, Class K 3 | 8740128 | Show | |
Chamber module LW 1000 ground Access LW 800, 2125-2374 mm, Class K 3 | 8740129 | Show | |
Chamber module LW 1000 ground Access LW 800, 2375-2624 mm, Class K 3 | 8740130 | Show | |
Chamber module LW 1000 ground Access LW 800, 2625-2874 mm, Class K 3 | 8740131 | Show | |
Chamber module LW 1000 ground Access LW 800, 2875-3124 mm, Class K 3 | 8740132 | Show | |
Chamber module LW 1000 ground Access LW 800, 3125-3374 mm, Class K 3 | 8740133 | Show | |
Chamber module LW 1000 ground Access LW 800, 3375-3624 mm, Class K 3 | 8740134 | Show | |
Chamber module LW 1000 ground Access LW 800, 3625-3874 mm, Class K 3 | 8740135 | Show | |
Chamber module LW 1000 ground Access LW 800, 3875-4124 mm, Class K 3 | 8740136 | Show | |
Chamber module LW 1000 ground Access LW 800, 620-869 mm, Class B | 8740141 | Show | |
Chamber module LW 1000 ground Access LW 800, 870-1119 mm, Class B | 8740142 | Show | |
Chamber module LW 1000 ground Access LW 800, 1120-1369 mm, Class B | 8740143 | Show | |
Chamber module LW 1000 ground Access LW 800, 620-869 mm, Class D | 8740158 | Show | |
Chamber module LW 1000 ground Access LW 800, 870-1119 mm, Class D | 8740159 | Show | |
Chamber module LW 1000 ground Access LW 800, 1120-1369 mm, Class D | 8740160 | Show |
Title | Item no. |
---|
Title | Item no. | ||
---|---|---|---|
Basic warning device with electronic probe | 20222 | Show | |
Basic warning device with optical probe | 20223 | Show | |
Compressor set for air bubbling | 28048 | Show | |
TeleControl GSM modem for Comfort control units 230V/400V | 28792 | Show | |
Connection box for level sensor extension | 28799 | Show | |
Intermediate section 250 mm, for chamber module LW 1000 | 680370 | Show | |
Intermediate section 500 mm, for chamber module LW 1000 | 680371 | Show | |
Replacement set optical probe | 80888 | Show | |
10 m probe cable extension set | 80889 | Show | |
Cable prolongation set for pump 10 m | 80891 | Show | |
Installation set Thermostat, Hygrostat | 97713 | Show | |
Outdoor control cabinet W: 590 mm, for control unit installation | 97714 | Show | |
Warning beacon for outdoor control cabinet | 97715 | Show | |
Outdoor control cabinet W: 460 mm, for control unit installation | 97716 | Show | |
Outdoor control cabinet W: 785 mm, for control unit installation | 97723 | Show | |
Outdoor control cabinet W: 1115 mm, for control unit installation | 97724 | Show |
Title | Item no. | ||
---|---|---|---|
Replacement set pump flange | 28051 | Show | |
Control unit Aqualift Comfort 230 V Duo | 28746 | Show | |
Battery 9 V block | 680034 | Show | |
Seal Pump flange | 680045 | Show | |
Screw set galvanised, 14 each | 680047 | Show | |
Pump flange SPF 1400 - SPF 4500 | 680050 | Show | |
Seal for SPF 1400 - SPF 4500 | 680052 | Show | |
Flap set Rolling ring, flap, flap holder | 680053 | Show | |
Pump drive SPF 1400 230 V, S3, 10 m cable, with capacitor | 680218 | Show | |
Immersion pipe for Aqualift F XL, 280 mm | 680388 | Show | |
Flap housing for Duo systems, with 2 shut-off valves | 680419 | Show | |
Cleaning cover screwed, DN 160 | 680421 | Show | |
Seal set Pump flange | 680422 | Show | |
Pressure piping DN 90 | 680423 | Show |
Catalog Page | |
---|---|
Manuals |
|
CAD Data | |
Test Reports and Certificates | |
Declaration of Performance | |
Declaration of Conformity | |
BIM Data |
- Installation situation (ATTR-1): underground installation
- TÜV test mark (ATTR-376): ID 1111241940
- Country of origin (ATTR-322): DE
- Area of application (ATTR-264): drainage
- Pump type (ATTR-265): Freestanding pump
- Pump shaft position (ATTR-266): vertical
- Pump design (ATTR-267): Dry rotor pump
- Pump hydraulics (ATTR-268): single stage
- Pump suction characteristic (ATTR-269): non-self-priming
- Pump drive (ATTR-270): E-motor for alternating current
- E-motor, type of startup (ATTR-271): direct
- Pump casing material (ATTR-272): Grey iron
- Upper tolerance of the operating voltage (+) (ATTR-273): 10 PROZ
- Lower tolerance of the operating voltage (-) (ATTR-274): 10 PROZ
- Upper tolerance of the nominal frequency (+) (ATTR-275): 3 PROZ
- Lower tolerance of the nominal frequency (-) (ATTR-276): 2 PROZ
- Pump electrical connection (ATTR-277): 1/N/PE 230V
- Motor pump shaft (ATTR-279): continuous
- Shaft seal (ATTR-280): RSSR
- Number of operating pumps (ATTR-281): 1
- Minimum pumped media temperature (ATTR-282): 0 CEL
- Maximum operating pressure (Pmax) (ATTR-283): 700 HPA
- Minimum speed for speed adjustment (ATTR-284): no speed adjustment
- Start-up current (ATTR-285): 23 AMP
- Vertical installation (ATTR-286): yes
- Operating mode, twin systems (ATTR-287): redundant
- Pump (ATTR-4): SPF 1400
- Number of pumps (ATTR-181): 2
- Impeller type (ATTR-8): Multi-vane impeller
- Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.5 mm2
- Max. permissible switching frequency (ATTR-162): 20 1PH
- Operating mode (ATTR-10): S3 - 50 %
- Power P1 (ATTR-F4): 1.6 KWT
- Power P2 (ATTR-F5): 1.1 KWT
- Speed (ATTR-F2): 1,370 UMIN
- Rated current (ATTR-N5): 7.3 AMP
- Max. pumping capacity (ATTR-F7): 38 MQH
- Max. pumping height (ATTR-F8): 7 MTR
- Max. temperature (permanent) of conveyed material (ATTR-132): 40 CEL
- Protection class (ATTR-133): I
- Connection type (ATTR-N1): coded plug
- Protection class (pump) (ATTR-125): IP 68 (3m/48h)
- Length of mains cable for pump (ATTR-11): 10 MTR
- Temperature monitoring (ATTR-135): integrated
- Weight (ATTR-191): 25 KGM
- Cos phi - power factor (ATTR-192): 1.0
- Insulation class (ATTR-193): F
- Expected service life (hours of operation) (ATTR-194): 5,000 HUR
- Expected service life (number of switching cycles) (ATTR-195): 150,000
- Net weight (ATTR-A3A): 204 KGM
- Gross weight (ATTR-A3B): 228 KGM
- Shut-off valve (ATTR-A1): Shut-off valve made of polymer
- Pressure pipe connection (ATTR-B7): horizontal
- Type of system (ATTR-2): Twin pump station
- Installation (ATTR-164): Dry installation
- Backflow preventer (ATTR-165): integrated
- Pump control (ATTR-134): Control unit
- Access steps (ATTR-182): yes
- Note on installation depth (ATTR-188): Version for deeper installation
- Length (ATTR-A6A): 1,295 MMT
- Width (ATTR-A6B): 1,295 MMT
- Height (ATTR-A6C): 1,403 MMT
- Volume (ATTR-320): 3.7 MTQ
- Packaging dimension: length (ATTR-325): 2,000 MMT
- Packaging dimension: width (ATTR-326): 1,300 MMT
- Packaging dimension: height (ATTR-327): 1,435 MMT
- Dimensions (ATTR-323): 1300X1300X1850MM/800X700X950
- Number of packages (ATTR-321): 1
- Control unit (ATTR-S2): Comfort
- Self-diagnosis system (SDS) (ATTR-S5): yes
- Battery buffering (ATTR-S6): yes
- Multi-line display (ATTR-S7): yes
- Log book function (ATTR-S8): yes
- USB interface (ATTR-S9): yes
- GSM interface (ATTR-S10): yes
- Potential-free contact (ATTR-S11): optional
- Length of mains cable for control unit (ATTR-S12): 1.4 MTR
- Operating voltage (ATTR-S13): 230 VLT
- Mains frequency (ATTR-S14): 50 HTZ
- Protection class control unit (ATTR-S4): IP 54
- Alarm sensor (ATTR-S1): Immersion pipe
- Type of level measurement (ATTR-7A): pneumatic
- Level measurement instrument (ATTR-7B): Immersion pipe
- Type of fuse required (electrical protection) (ATTR-S17): C 16 A
- Clear width of tank (LW) (ATTR-B14): 1,000 MMT
- Number of inlets (ATTR-B1B): 1 PCE
- Inlet nominal size (DN) (ATTR-B1CA): 150 MMT
- Inlet nominal size (OD) (ATTR-B1CB): 160 MMT
- Distance from centre of inlet pipe to tank bottom (ATTR-B6): 833 MMT
- Distance pipe bottom inlet to tank bottom (ATTR-B1D): 753 MMT
- Distance from centre of outlet pipe to tank bottom (ATTR-B15E): 1,300 MMT
- Venting connection (DN) (ATTR-B4): 70 MMT
- Pressure pipe connection (DN) (ATTR-B17): 80 MMT
- Pressure pipe connection (OD) (ATTR-B18): 90 MMT
- Tank volume (ATTR-B9): 335 LTR
- Pumping volume (ATTR-B10): 160 LTR
- Groundwater resistant from lower edge of base section (ATTR-B12): 3,000 MMT
- Distance from inlet pipe invert to top of tank (ATTR-318): 650 MMT
- Colour (ATTR-102): black
- Standard (ATTR-9): EN 12050-1
- CE marking (ATTR-A5B): yes
- External monitoring (ATTR-A8): LGA
- Free passage (ATTR-180): 40 MMT
- Delivery state (ATTR-189): Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected)
- Declaration of Performance (DOP) (ATTR-292): 009-034
- Wastewater quantity (ATTR-310): High
- Type of wastewater (ATTR-6): wastewater with sewage
- Declaration of conformity (ATTR-303): 009-034-D
- Brand (M-ATTR-001): KESSEL
- Product group (M-ATTR-002): Lifting stations
- Product type (M-ATTR-003): Pumping station
- Product family (M-ATTR-004): Aqualift
- Product name (M-ATTR-005): Aqualift F XL