Tronic, GTF1400-S1, level sensor

Aqualift F retrofit kit, wet installation, with GTF1400-S1 pump for installation in an on-site chamber module. - for faecal and faecal-free wastewater (not approved for use in an ATEX zone) - pressure pipe preassembled in the factory with backflow preventer and shut-off valve - pump(s) with multi-vane impeller for maximum operating reliability - including level sensor for level measurement - including Comfort 230 V control unit - required minimum diameter of on-site chamber module: 1000 mm

Item no. GTF1400-M
Price group 60

    Kit Aquapump Retrofit Tronic, GTF1400-S1, level sensor
    Aqualift F retrofit kit, wet installation, with GTF1400-S1 pump for installation in an on-site chamber module. - for faecal and faecal-free wastewater (not approved for use in an ATEX zone) - pressure pipe preassembled in the factory with backflow preventer and shut-off valve - pump(s) with multi-vane impeller for maximum operating reliability - including level sensor for level measurement - including Comfort 230 V control unit - required minimum diameter of on-site chamber module: 1000 mm Type of wastewater: wastewater with sewage Installation situation: installation in on-site collecting tank Version: Type of system: Single station Shut-off valve: yes Pump control: Control unit Backflow preventer: integrated Delivery state: Modular set for assembly on site General characteristics: Standard: EN 12050-2 Tank: Inlet nominal size (DN): 150 Pressure pipe connection: horizontal Pressure pipe connection (DN): 50 mm Pressure pipe connection (OD): 63 mm Pumping device: Pump: GTF 1400 Number of pumps: 1 Max. pumping capacity: 31 m3/h Max. pumping height: 10.5 m Operating voltage: 230 V Mains frequency: 50 Hz Operating mode: S1 Power P1: 1.5 kW Power P2: 1.1 kW Speed: 2,900 U/min Type of fuse required (electrical protection): C 16 A Max. temperature (permanent) of conveyed material: 40 °C Connection type: coded plug Weight: 12 kg Impeller type: Multi-vane impeller Length of mains cable for pump: 10 m Rated current: 6.5 A Protection class (pump): IP 68 (3m) Protection class: I Type of pump connection cable: H07RN-F 3G 1.0 mm2 Temperature monitoring: integrated Control: Control unit: Comfort Operating voltage: 230 V Mains frequency: 50 Hz Self-diagnosis system (SDS): yes Battery buffering: yes Multi-line display: yes Log book function: yes USB interface: yes GSM interface: yes Potential-free contact: optional Type of fuse required (electrical protection): C 16 A Protection class control unit: IP 54 Length of mains cable for control unit: 1.4 m Type of level measurement: pneumatic Level measurement instrument: Submersible pressure switch Alarm sensor: optical probe
      Title Item no.  
      Title Item no.  
      Title Item no.  
      Title Item no.  
    Catalog Page
    • Type of wastewater (ATTR-6): wastewater with sewage
    • Pump (ATTR-4): GTF 1400
    • Number of pumps (ATTR-181): 1
    • Impeller type (ATTR-8): Multi-vane impeller
    • Operating mode (ATTR-10): S1
    • Power P1 (ATTR-F4): 1.5  KWT
    • Power P2 (ATTR-F5): 1.1  KWT
    • Operating voltage (ATTR-131): 230  VLT
    • Mains frequency (ATTR-N4): 50  HTZ
    • Rated current (ATTR-N5): 6.5  AMP
    • Max. pumping capacity (ATTR-F7): 31  MQH
    • Max. pumping height (ATTR-F8): 10.5  MTR
    • Protection class (pump) (ATTR-125): IP 68 (3m)
    • Length of mains cable for pump (ATTR-11): 10  MTR
    • Number of packages (ATTR-321): 0
    • Shut-off valve (ATTR-A1): yes
    • Type of system (ATTR-2): Single station
    • Backflow preventer (ATTR-165): integrated
    • Inlet nominal size (DN) (ATTR-B1CA): 150  MMT
    • Pumping volume (ATTR-B10): 350  LTR
    • Control unit (ATTR-S2): Comfort
    • Self-diagnosis system (SDS) (ATTR-S5): yes
    • Multi-line display (ATTR-S7): yes
    • GSM interface (ATTR-S10): yes
    • Potential-free contact (ATTR-S11): optional
    • Mains frequency (ATTR-S14): 50  HTZ
    • Level measurement instrument (ATTR-7B): Submersible pressure switch
    • Brand (M-ATTR-001): KESSEL
    • Product group (M-ATTR-002): Lifting stations
    • Product type (M-ATTR-003): Pumping station
    • Product family (M-ATTR-004): Aqualift F XL
    • Product name (M-ATTR-005): Aqualift F XL
    • Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.0 mm2
    • Type of fuse required (electrical protection) (ATTR-N3): C 16 A
    • Speed (ATTR-F2): 2,900  UMIN
    • Max. temperature (permanent) of conveyed material (ATTR-132): 40  CEL
    • Protection class (ATTR-133): I
    • Connection type (ATTR-N1): coded plug
    • Temperature monitoring (ATTR-135): integrated
    • Weight (ATTR-191): 12  KGM
    • Pressure pipe connection (ATTR-B7): horizontal
    • Pump control (ATTR-134): Control unit
    • Pressure pipe connection (DN) (ATTR-B17): 50  MMT
    • Pressure pipe connection (OD) (ATTR-B18): 63  MMT
    • Battery buffering (ATTR-S6): yes
    • Log book function (ATTR-S8): yes
    • USB interface (ATTR-S9): yes
    • Length of mains cable for control unit (ATTR-S12): 1.4  MTR
    • Operating voltage (ATTR-S13): 230  VLT
    • Protection class control unit (ATTR-S4): IP 54
    • Alarm sensor (ATTR-S1): optical probe
    • Type of level measurement (ATTR-7A): pneumatic
    • Type of fuse required (electrical protection) (ATTR-S17): C 16 A
    • Standard (ATTR-9): EN 12050-2
    • Installation situation (ATTR-1): installation in on-site collecting tank
    • Delivery state (ATTR-189): Modular set for assembly on site